Solar Street Light
All-in-one and all-in-two solar street lights in a 50W–300W range, with LiFePO4 storage and project-specific panels, poles and controls.
Poles & Traffic
Galvanized steel lighting poles supplied through Mast Lighting, with qualified size, material and finish references. Final structure and supply scope require project-specific confirmation.
Overview
Mast Lighting supplies lighting poles as an agent/distributor of Zijun Lighting for importers, municipal buyers and project contractors. This category covers galvanized steel light pole enquiries, with 6 m, 8 m, 10 m and 12 m as established enquiry sizes. They are not confirmed stock items or pre-approved structural configurations.
The gallery contains six original views from the supplier's Lighting Pole listing. ZJ-004 is that supplier's reference, not a Mast Lighting SKU. The images and broad parameter lists do not establish one common specification, nor do pictured fittings define the quoted supply scope.
The supplier lists a broader 3–40 m height range and 2.5–20 mm wall thickness range independently. The selected height, section, material, arms, attached equipment and site conditions need a coordinated design. Do not combine the endpoints into a configuration. For taller area-lighting requirements, also review high mast lighting.
A pole quotation must identify the shaft, arms, finish, connections and each accessory. Anchor cages, foundations, LED street lights and solar-panel mounting hardware are not automatically included. Compatibility with solar street lights or other equipment requires the mounting geometry, weights and projected areas to be reviewed.
Mast Lighting coordinates requirements with its manufacturing partner; factory credentials are not Mast Lighting manufacturing credentials. Request the current supplier datasheet, selected drawing revision, material records, coating and weld inspection documentation, and project-specific structural evidence. ASTM A123 and AWS D1.1 are references in the source, not verified conformity claims for every pole.
OEM/ODM requests can cover pole geometry, interfaces, finish, labeling and packaging. Free Dialux lighting design can support the lighting layout, but does not replace structural, foundation or electrical checks. Start with your project location, quantity, intended height and application; unresolved inputs can be discussed before the scope is finalized.
Technical parameters
Compare these category parameters with your project requirements. Confirm configurable values and supporting documentation for the selected model before ordering. Free Dialux lighting design supports the lighting layout only. Pole geometry, equipment loads, anchorage, foundations and electrical provisions require separate project checks.
| Product identity | Lighting Pole is a category supplied through Mast Lighting, an agent/distributor of Zijun Lighting. ZJ-004 is the supplier reference, not a Mast Lighting SKU or confirmation that all six photos share one specification. |
|---|---|
| Height reference | The supplier lists 3–40 m across its pole offering. This broad range does not confirm a particular shaft, wall thickness, load rating or foundation. Request a configuration-specific drawing. |
| Enquiry heights | 6 m, 8 m, 10 m and 12 m are established enquiry sizes for this category, not confirmed stock or standardized engineered assemblies. Other heights require supplier review. |
| Wall thickness reference | 2.5–20 mm is listed independently of height and material. Do not pair heights and thicknesses without the selected design and load calculations. |
| Section profiles and arms | Round, polygonal and tapered forms, with single- or double-arm options, are supplier-listed. Confirm cross-section, taper, arm outreach, orientation and connection dimensions on the drawing. |
| Section length and joints | The source describes sections up to 12 m formed without a slip joint and separately lists insert, internal-flange and face-to-face joints. It does not map joint types or section counts to overall pole heights. |
| Steel grade selection | The source mentions Q235 and Q345, and separately Q235B, Q345B and other material designations. Specify the exact standard, grade and thickness; request material records. No grade equivalence or height-to-grade pairing is established here. |
| Material-property limits | The source does not link its strength figures to a defined material, thickness or test record. No universal yield or tensile strength is assigned. An aluminum mention in a generic field is not confirmation of an offered aluminum configuration. |
| Fabrication process | The supplier describes material checks, cutting, forming/bending, longitudinal welding, dimensional checks, flange welding, drilling, deburring and finishing. Confirm the manufacturing and inspection plan for the selected pole. |
|---|---|
| Welding method | Submerged-arc welding and internal/external welding are supplier descriptions. Weld preparation, weld sizes, access details and inspection acceptance criteria require approved drawings and procedures. |
| Welding-standard reference | AWS D1.1 is cited by the supplier. The listing does not provide a project-matched procedure, qualification or inspection report; compliance is not verified by this page. |
| Hot-dip galvanizing | Hot-dip galvanizing with an ASTM A123 reference is supplier-listed, not a verified coating certificate for every pole. Confirm the agreed edition, coverage, required coating thickness and inspection results. |
| Color and coating options | Powder coating and RAL colors are listed. Confirm the specified color, coating system, substrate preparation and whether coating over galvanizing is included. No coating thickness is imported from another product category. |
| Corrosion and service life | No universal corrosion-life or twenty-year service-life guarantee is established. Confirm exposure conditions, coating requirements, maintenance guidance and written warranty terms for the selected supply. |
| Inspection and documentation | Request material records, dimensional and weld inspection records, coating measurements and approved drawings. Supplier references to flaw testing and ISO9001 do not establish test results or structural approval for the quoted pole. |
| Wind and seismic design | Suitability requires site-specific design criteria, applicable standards and configuration-specific calculations. The source wind and seismic statements do not establish a universal typhoon or earthquake rating. |
|---|---|
| Attached equipment and loads | Provide luminaire and accessory weights, projected areas, mounting heights and arm geometry for review. Panel mounts, signs, cameras or other additions require explicit assessment; no allowable load is inferred from the photos. |
| Shaft and base dimensions | Top and bottom diameters, taper, base-plate dimensions, bolt-circle geometry and opening reinforcement are not fixed by the listing. Confirm all interfaces against the approved drawing. |
| Anchorage and foundations | Anchor bolts, anchor cages, templates and foundations are not assumed included. Confirm the supply boundary and obtain site-specific foundation and anchorage design before installation. |
| Electrical access and bonding | Access-door size and location, cable routing, bonding provisions and terminal hardware are quotation-confirmation items. A pole listing does not establish complete electrical-installation compliance. |
| Luminaire specifications excluded | The source also includes HPS/MH lamp power, AC supply, IP65 and lighting-fixture temperature information. These are not structural pole ratings, not a confirmed LED package and not proof that luminaires are included. |
| Unresolved weight and tolerance | The source weight and dimensional-tolerance entries have no usable configuration or measurement basis. Request the finished-pole mass and dimension-specific tolerances rather than using those entries for ordering. |
| Project approval and installation | Confirm the required structural review, foundation responsibilities, lifting plan, assembly instructions and inspection requirements. Free Dialux lighting design supports the lighting layout, not pole or foundation structural approval. |
| What the quotation must identify | Selected pole geometry, exact material, finish, arms, connections, accessories, drawings and applicable documentation. Only items expressly listed in the quotation form the supply scope. |
|---|---|
| OEM/ODM requests | Submit height, profile, arm arrangement, mounting interfaces, labeling and packaging requirements through Mast Lighting for manufacturing-partner review. Feasibility and commercial terms require confirmation. |
| Packing and shipping dimensions | The source describes several packing approaches. Agree protection, packing method, section lengths and gross weights for the selected shipment; the listing does not fix one packing specification. |
| Container quantity | Loading quantity must be calculated from the actual pole dimensions, packaging and shipment mix. No pieces-per-container figure is confirmed by the source. |
| Datasheet and drawing request | Ask for the current supplier datasheet and a configuration-specific drawing with its revision. General catalog information does not replace the approved order documents. |
| Warranty | No pole-specific warranty period is established by this source. Confirm the responsible party, covered items, exclusions and claim process in writing; a luminaire warranty is not automatically a pole warranty. |
| Price, availability and lead time | Quantity, geometry, material, finish, accessories, evidence requirements and destination determine the quotation. No price, stock level, MOQ, sample availability or delivery promise is stated here. |
Where it is used
These are application scenarios to assess, not completed project references. Confirm site-specific lighting and safety criteria. See our lighting solutions for broader planning context.
Configurable
Mast Lighting coordinates OEM/ODM customization with its manufacturing partner. Submit pole geometry, material, finish, arms, connections, labeling and packaging requirements for review. Availability, compatibility and quoted inclusions require written confirmation.
Product questions
Commercial questions on MOQ, samples, lead time, shipping and warranty are collected on the FAQ page.
Explore the range
All-in-one and all-in-two solar street lights in a 50W–300W range, with LiFePO4 storage and project-specific panels, poles and controls.
AC LED street lights with supplier-listed 120W, 240W and 320W options, IP65 protection and 3000–6500 K CCT choices; final configurations confirmed by project.
High mast lighting for large-area projects, with original supplier photos, qualified luminaire specifications and project-specific mast engineering requirements.
Decorative garden lights for parks, residential grounds and walkways, with original supplier photos and electrical, pole and finish details for project review.
Enquire
Start with your contact details, project location, quantity, application and requested pole height. If available, include a drawing reference, arm arrangement, attached equipment weights and projected areas, design criteria, finish and required accessories. Missing inputs can be discussed; final scope, supporting documents and commercial terms require written confirmation.